Welcome to our websites!

WPLUA Integral type Ex-proof Vortex Flowmeter

Short Description:

WPLUA Integral type Vortex Flowmeters are versatile flow measurement solutions for all kinds of process media by employing Karman vortex street. The flowmeter is suitable for both conducting and non-conducting liquids as well as all industrial gases. With no moving parts in the primary flow stream, the integral vortex flowmeter is known for high durability, low maintenance, and suitability for a wide range of industrial applications, including process control and energy management.

 

 


Product Detail

Product Tags

Application

WPLUA Vortex Flowmeters is ideal choice for industrial flow measurement and control in a variety of area:

  • ✦ Oil & Gas
  • ✦ Pulp & Paper
  • ✦ Marine & Offshore
  • ✦ Food & Beverage
  • ✦ Metal & Mining
  • ✦ Energy Management
  • ✦ Trade Settlement

Description

WPLUA Integral Vortex Flowmeter combines converter and flow sensor together. It can be integrated with pressure and temperature compensation to improve reliability and measurement accuracy, avoid errors caused by fluctuations of temperature and pressure, especially for gases and heated steam. The flameproof structure further ensures the reliable and safe operation under in complex and dynamic working environment.

Feature

Wide scope of applications for liquid, gas and steam

Simple structure, no moving parts, high reliability

4~20mA or pulse output with LCD local display

Explosion proof model for harsh condition

Temperature and pressure compensation

Integral and split structures available

High measurement accuracy, low pressure loss

Easy installation by flange, clamp or plug-in

Principle

The operation of WPLU vortex flowmeter is based on the principle that vortices are formed downstream of an obstacle in a fluid flow, e.g. behind a bridge pillar which is commonly known as the Karman vortex street. When the fluid flows past a bluff body in the measuring tube, vortices are alternately formed on each side of this body. The frequency of vortex shedding down each side of the bluff body is directly proportional to mean flow velocity and therefore to volume flow. As they shed in the downstream flow, each of the alternating vortices creates a local low pressure area in the measuring tube. This is detected by a capacitive sensor and fed to the electronic processor as a primary, digitized, linear signal. The measuring signal is not subject to drift. Consequently, vortex flowmeters can operate an entire life long without recalibration.

Specification

Name Integral type Vortex Flowmeter
Model WPLUA
Medium Liquid, Gas, Steam (Avoid Multiphase Flow and Sticky Fluids)
Accuracy Liquid: ±1.0%of readingGas(steam): ±1.5%of readingPlug-in type: ±2.5%of reading
Operation pressure 1.6MPa,2.5MPa,4.0MPa,6.4MPa
Medium temperature -40~150℃ standard-40~250℃ Middle temperature type-40~350℃special  
Output signal 2-wire: 4~20mA3-wire: 0~10mA or pulse
Communication: HART
Ambient Temperature -35℃~+60℃
Humidity ≤95%RH
Indicator  LCD
Installation Flange; Clamp; Plug-in
Supply Voltage 24VDC
Housing material Body: Carbon steel; Stainless steel; Hastelloy
Converter: Aluminum alloy; Stainless steel
Explosion-proof Intrinsically safe; Flameproof
For more information about WPLUA Vortex Flowmeter, please feel free to contact us.